Product
App
Support
CHU/CU Series
With over 60 years of experience in heat pump development, Sharp’s CHU/CU Series delivers reliable, year-round comfort without compromising performance. Engineered to withstand harsh cold climates, it consistently provides heating even at temperatures as low as -30°C. Its smart, modern design also blends seamlessly into any environment.
Main Features :
Energy Start Cold Climate Certified
Available in Single & Multi Zone Configuration
Motion Sensor (CHU Variant Only)
Safe “Hot Gas Pipe” de-icing system
Built in Wi-Fi Functionality
50ft long Coanda Airflow
Available Capacities:
24,000 BTU
18,000 BTU
15,000 BTU
12,000 BTU
9,000 BTU
Motion Sensor Technology
The CHU Series features a built-in Motion Sensor that optimizes comfort and efficiency by monitoring human activity in the room. If no movement is detected for a set period, the system automatically adjusts cooling or heating to conserve energy. Once movement is detected, it quickly restores the original settings, ensuring the room returns to your preferred comfort level without delay. This smart function provides consistent comfort while minimizing unnecessary energy use. (CHU Variant Only)
Single & Multi-Zone Configuration
Available in both single-zone and multi-zone configurations, the
system provides flexibility to meet a wide range of needs. A single-zone setup efficiently
conditions one specific room or area, while a multi-zone option allows up to three indoor units
to connect to a single outdoor unit. This adaptable design makes it easy to create tailored
comfort solutions for homes, offices, and commercial spaces.
The illustration shows a configuration using three AY-XPC12CU indoor
units paired with one AE-X3M24CU outdoor unit.
The AE-X3M24CU outdoor unit is designed for multi-zone configurations. Please refer to the
specifications for other possible combinations.
Maintain with Ease
The new CHU/CU heat pump is thoughtfully designed for easy maintenance, helping you keep it in top condition with minimal effort. The air filter can be removed in seconds and cleaned with a simple hand vacuum about once every three months. For deeper cleaning, the top panel of the unit can also be detached effortlessly, allowing convenient access to interior components. A quick wipe with a soft cloth keeps the entire indoor unit looking fresh and dust-free.
Coanda Airflow Technology
With Coanda Airflow technology, the unit delivers smooth, far-reaching airflow that spreads evenly throughout the room. It maintains strong air delivery up to 50 feet (15 meters), providing consistent cooling and heating to every corner.
Tested for Harsh Cold Climate
CHU/CU series units are carefully engineered to deliver stable performance even under extreme weather conditions. Each model undergoes rigorous testing to ensure reliable operation in harsh environments, including freezing temperatures down to -30°C. Designed with durability and consistency in mind, the system provides dependable heating throughout the coldest seasons while maintaining comfort indoors. This combination of advanced engineering and strict quality control ensures long-lasting performance you can rely on year after year.
Keep the Inside Clean
With the AFTER CARE feature, your unit stays clean and efficient with little effort. After each use, the indoor unit runs in fan mode to gently dry its interior, reducing odors and preventing mold. This simple process helps maintain consistent airflow, long-lasting performance, and a fresher indoor environment—without the need for frequent manual cleaning.
Unit Measurement
Indoor Unit
(AY-XP12CHU,
AY-XP18CHU)
Indoor Unit
(AY-XP15CU, AY-XPC18CU,
AY-XP24CU)
Indoor Unit
(AY-XPC12CU,
AY-XPC9CU)
Outdoor Unit
(AE-X18CHU, AE-X18CU,
AE-X24CU)
Outdoor Unit
(AE-X12CHU, AE-X15CU,
AE-X12CU)
Outdoor Unit
(AE-X3M24CU)
For Multi
Zone Configuration
※ All measurements is in milimeter
Color Variation
Premium White
Available for all
model
Dark Gray
Only available in this model:
AY-XP12CHU-B, AY-XP15CU-B, AY-XPC18CU-B
Other Parts
Remote
Control
Specification
CHU Series | Single Zone Model
Indoor Unit
AY-XP12CHU, AY-XP12CHU-B
Outdoor Unit
AE-X12CHU
AHRI Number
217512736 (AY-XP12CHU) | 217512733 (AY-XP12CHU-B)
Rated Cooling Capacity
12,000 (3,500 - 14,000)
Rated Heating Capacity
16,000 (3,100 - 22,850)
Max Heating Capacity
at 5°F (-15°C)
at -4°F (-20°C)
at -13°F (-25°C)
at -17°F (-27°C)
at -22°F (-30°C)
16,000
13,800
11,600
11,200
9,700
EER2
16.0
SEER/SEER2
25.0 / 25.0
HSPF/HSPF2 (IV)
12.0 / 11.0
HSPF/HSPF2 (V)
9.6 / 9.0
COP at 5°F (-15°C)
2.1
Power Supply
208/230V, 1-Phase, 60Hz
Max Fuse Size (A)
20
Sound Pressure (dB)
Cooling (IDU)
Cooling (ODU)
Heating (IDU)
Heating (ODU)
43 / 40 / 36 / 28 / 24
49
44 / 40 / 35 / 29 / 22
50
Airflow Rate (cfm)
Cooling
Heating
597 / 519 / 403 / 290 / 212
636 / 558 / 466 / 374 / 212
Operating Range
Cooling
Heating
14 to 115°F (-10 to 46°C)
-22 to 75°F (-30 to 24°C)
Pipe Diameter
1/4 x 3/8
Refrigerant
R32
Ref. Volume oz (g)
36 (1020)
Pipe length ft (m)
10 (3) - 25 (7.6)
w/ add. refrigerant
25 (7.6) - 66 (20)
Max height ft (m)
33 (10)
Add charge oz/ft (g/m)
0.16 (15)
Indoor Unit
AY-XP18CHU
Outdoor Unit
AE-X18CHU
AHRI Number
217508925
Rated Cooling Capacity
18,000 (6,000 - 21,600)
Rated Heating Capacity
21,600 (5,500 - 30,000)
Max Heating Capacity
at 5°F (-15°C)
at -4°F (-20°C)
at -13°F (-25°C)
at -17°F (-27°C)
at -22°F (-30°C)
19,500
17,100
14,800
12,700
11,800
EER2
13.0
SEER/SEER2
24.0 / 25.0
HSPF/HSPF2 (IV)
13.0 / 11.5
HSPF/HSPF2 (V)
10.0 / 9.0
COP at 5°F (-15°C)
2.2
Power Supply
208/230V, 1-Phase, 60Hz
Max Fuse Size (A)
25
Sound Pressure (dB)
Cooling (IDU)
Cooling (ODU)
Heating (IDU)
Heating (ODU)
45 / 43 / 38 / 31 / 28
52
49 / 47 / 41 / 31 / 25
52
Airflow Rate (cfm)
Cooling
Heating
636 / 597 / 480 / 328 / 251
752 / 713 / 558 / 403 / 290
Operating Range
Cooling
Heating
14 to 115°F (-10 to 46°C)
-22 to 75°F (-30 to 24°C)
Pipe Diameter
1/4 x 3/8
Refrigerant
R32
Ref. Volume oz (g)
49 (1390)
Pipe length ft (m)
10 (3) - 25 (7.6)
w/ add. refrigerant
25 (7.6) - 66 (20)
Max height ft (m)
33 (10)
Add charge oz/ft (g/m)
0.16 (15)
CU Series | Single Zone Model
Indoor Unit
AY-XPC12CU
Outdoor Unit
AE-X12CU
AHRI Number
217512740
Rated Cooling Capacity
12,000 (2,800 - 13,600)
Rated Heating Capacity
14,000 (3,200 - 19,000)
Max Heating Capacity
at 5°F (-15°C)
at -4°F (-20°C)
at -13°F (-25°C)
at -17°F (-27°C)
at -22°F (-30°C)
12,700
10,700
9,000
8,000
-
EER2
12.5
SEER/SEER2
21.0 / 22.0
HSPF/HSPF2 (IV)
12.5 / 11.0
HSPF/HSPF2 (V)
9.6 / 9.0
COP at 5°F (-15°C)
2.1
Power Supply
208/230V, 1-Phase, 60Hz
Max Fuse Size (A)
15
Sound Pressure (dB)
Cooling (IDU)
Cooling (ODU)
Heating (IDU)
Heating (ODU)
42 / 39 / 34 / 27 / 23
49
43 / 40 / 35 / 28 / 23
50
Airflow Rate (cfm)
Cooling
Heating
438 / 385 / 307 / 219 / 145
438 / 385 / 318 / 254 / 145
Operating Range
Cooling
Heating
14 to 115°F (-10 to 46°C)
-17 to 75°F (-27 to 24°C)
Pipe Diameter
1/4 x 3/8
Refrigerant
R32
Ref. Volume oz (g)
33.2 (940)
Pipe length ft (m)
10 (3) - 25 (7.6)
w/ add. refrigerant
25 (7.6) - 66 (20)
Max height ft (m)
33 (10)
Add charge oz/ft (g/m)
0.16 (15)
Indoor Unit
AY-XP15CU, AY-XP15CU-B
Outdoor Unit
AE-X15CU
AHRI Number
217512734 (AY-XP15CU) | 217508926 (AY-XP15CU-B)
Rated Cooling Capacity
15,000 (5,000 - 17,000)
Rated Heating Capacity
18,000 (4,500 - 21,800)
Max Heating Capacity
at 5°F (-15°C)
at -4°F (-20°C)
at -13°F (-25°C)
at -17°F (-27°C)
at -22°F (-30°C)
15,300
13,200
11,100
10,100
8,900
EER2
13.4
SEER/SEER2
24.0 / 24.0
HSPF/HSPF2 (IV)
11.8 / 11.0
HSPF/HSPF2 (V)
9.5 / 8.7
COP at 5°F (-15°C)
2.1
Power Supply
208/230V, 1-Phase, 60Hz
Max Fuse Size (A)
20
Sound Pressure (dB)
Cooling (IDU)
Cooling (ODU)
Heating (IDU)
Heating (ODU)
46 / 42 / 38 / 30 / 26
49
46 / 42 / 36 / 30 / 23
50
Airflow Rate (cfm)
Cooling
Heating
636 / 558 / 441 / 328 / 251
674 / 597 / 505 / 413 / 251
Operating Range
Cooling
Heating
14 to 115°F (-10 to 46°C)
-22 to 75°F (-30 to 24°C)
Pipe Diameter
1/4 x 3/8
Refrigerant
R32
Ref. Volume oz (g)
36 (1020)
Pipe length ft (m)
10 (3) - 25 (7.6)
w/ add. refrigerant
25 (7.6) - 66 (20)
Max height ft (m)
33 (10)
Add charge oz/ft (g/m)
0.16 (15)
Indoor Unit
AY-XPC18CU, AY-XPC18CU-B
Outdoor Unit
AE-X18CU
AHRI Number
217508915 (AY-XPC18CU) | 217508914 (AY-XPC18CU-B)
Rated Cooling Capacity
18,000 (6,000 - 21,600)
Rated Heating Capacity
21,600 (5,500 - 27,000)
Max Heating Capacity
at 5°F (-15°C)
at -4°F (-20°C)
at -13°F (-25°C)
at -17°F (-27°C)
at -22°F (-30°C)
19,000
15,000
12,000
11,500
9,200
EER2
13.0
SEER/SEER2
24.0 / 24.0
HSPF/HSPF2 (IV)
13.0 / 11.0
HSPF/HSPF2 (V)
10.0 / 9.0
COP at 5°F (-15°C)
2.2
Power Supply
208/230V, 1-Phase, 60Hz
Max Fuse Size (A)
25
Sound Pressure (dB)
Cooling (IDU)
Cooling (ODU)
Heating (IDU)
Heating (ODU)
45 / 43 / 38 / 31 / 28
52
49 / 47 / 41 / 31 / 25
52
Airflow Rate (cfm)
Cooling
Heating
636 / 597 / 480 / 328 / 251
752 / 713 / 558 / 403 / 290
Operating Range
Cooling
Heating
14 to 115°F (-10 to 46°C)
-22 to 75°F (-30 to 24°C)
Pipe Diameter
1/4 x 3/8
Refrigerant
R32
Ref. Volume oz (g)
49 (1390)
Pipe length ft (m)
10 (3) - 25 (7.6)
w/ add. refrigerant
25 (7.6) - 66 (20)
Max height ft (m)
33 (10)
Add charge oz/ft (g/m)
0.16 (15)
Indoor Unit
AY-XP24CU
Outdoor Unit
AE-X24CU
AHRI Number
217508895
Rated Cooling Capacity
22,000 (6,000 - 24,000)
Rated Heating Capacity
24,000 (5,500 - 27,100)
Max Heating Capacity
at 5°F (-15°C)
at -4°F (-20°C)
at -13°F (-25°C)
at -17°F (-27°C)
at -22°F (-30°C)
19,000
16,400
13,900
12,300
10,500
EER2
10.0
SEER/SEER2
19.0 / 22.0
HSPF/HSPF2 (IV)
12.3 / 11.0
HSPF/HSPF2 (V)
9.6 / 8.5
COP at 5°F (-15°C)
2.2
Power Supply
208/230V, 1-Phase, 60Hz
Max Fuse Size (A)
25
Sound Pressure (dB)
Cooling (IDU)
Cooling (ODU)
Heating (IDU)
Heating (ODU)
47 / 45 / 40 / 33 / 30
53
49 / 47 / 41 / 31 / 25
54
Airflow Rate (cfm)
Cooling
Heating
674 / 636 / 519 / 367 / 290
752 / 713 / 558 / 403 / 290
Operating Range
Cooling
Heating
14 to 115°F (-10 to 46°C)
-22 to 75°F (-30 to 24°C)
Pipe Diameter
1/4 x 3/8
Refrigerant
R32
Ref. Volume oz (g)
49 (1390)
Pipe length ft (m)
10 (3) - 25 (7.6)
w/ add. refrigerant
25 (7.6) - 66 (20)
Max height ft (m)
33 (10)
Add charge oz/ft (g/m)
0.16 (15)
CU Series | Multi Zone Configuration
Below is one of the many possible combinations for multi-zone configurations.
Indoor Unit
AY-XPC12CU (3 Unit)
Outdoor Unit
AE-X3M24CU
AHRI Number
217512785
Rated Cooling Capacity
24,000 (5,500 - 27,000)
Rated Heating Capacity
26,000 (8,800 - 30,000)
Max Heating Capacity
at 5°F (-15°C)
at -4°F (-20°C)
at -13°F (-25°C)
at -17°F (-27°C)
at -22°F (-30°C)
21,200
18,600
15,700
14,600
13,000
EER2
14.0
SEER/SEER2
25.0 / 24.0
HSPF/HSPF2 (IV)
12.0 / 11.5
HSPF/HSPF2 (V)
9.7 / 9.0
COP at 5°F (-15°C)
2.3
Power Supply
208/230V, 1-Phase, 60Hz
Max Fuse Size (A)
25
Sound Pressure (dB)
Cooling (IDU)
Cooling (ODU)
Heating (IDU)
Heating (ODU)
42 / 39 / 34 / 27 / 23
52
43 / 40 / 35 / 28 / 23
53
Airflow Rate (cfm)
Cooling
Heating
438 / 385 / 307 / 219 / 145
438 / 385 / 318 / 254 / 145
Operating Range
Cooling
Heating
14 to 115°F (-10 to 46°C)
-22 to 75°F (-30 to 24°C)
Pipe Diameter
1/4 x 3/8 (x3)
Refrigerant
R32
Ref. Volume oz (g)
77.6 (2200)
Pipe length ft (m)
10 (3) - 98 (30)
w/ add. refrigerant
10(3) - 82(25) per IDU / 30(9) - 230(70) total lenght
Max height ft (m)
33(10)
Add charge oz/ft (g/m)
0.11 (10)
Click here for other possible combinations of multi-zone configurations
Configuration SheetContact Us
Canada Region
RBL A/C Inc.