Error Code
| Content of Diagnosis
|
1-0 |
Heat exchanger thermistor short circuit error |
1-1 |
Outdoor temperature thermistor short circuit error |
1-2 |
Suction thermistor short circuit error |
1-3 |
2-way valve thermistor short circuit error |
1-4 |
Heat sink thermistor short circuit error |
2-0 |
Compressor high temperature error |
2-1 |
Compressor discharge overheat |
2-2 |
Outdoor unit heat exchanger overheat |
2-3 |
Indoor unit heat exchanger overheat |
2-4 |
IPM high temperature error |
2-5 |
IPM high temperature error |
3-0 |
Temporary stop due to dehumidifying operation |
5-0 |
Heat exchanger thermistor open circuit error |
5-1 |
Outdoor temperature thermistor open circuit error |
5-2 |
Suction thermistor open circuit error |
5-3 |
2-way valve thermistor open circuit error |
5-4 |
Discharge thermistor open circuit error |
5-5 |
Heat sink thermistor open circuit error |
6-0 |
DC over current error |
6-1 |
IPM pin level error |
7-0 |
AC over current error |
7-1 |
AC current error when OFF |
7-2 |
AC maximum current error |
7-3 |
AC current deficiency error |
9-0 |
Thermistor installation error or 4-way valve error |
9-3 |
Compressor torque control error |
9-4 |
4 way valve error or Gas leak error |
9-5 |
2-way valve and 3-way valve close error |
9-6 |
Solenoid valve error |
10-0 |
EEPROM (Outdoor) data error |
10-1 |
EEPROM (Outdoor) data error |
10-2 |
CPU (Outdoor) RAM data error |
11-0 |
Outdoor unit DC fan rotation error |
11-1 |
Outdoor unit DC fan driver IC error |
11-2 |
Outdoor unit DC fan lock error |
11-3 |
Detection error of DC fan negative rotation before compressor is driven |
11-4 |
Detection error of inverter current for DC fan |
11-5 |
Outdoor unit DC fan open connector error |
12-0 |
Thermal fuse error in terminal board (for power supply) |
13-0 |
Compressor startup error |
13-1 |
Compressor rotation error (At 120°energizing) |
13-2 |
Compressor rotation error (At 180°energizing) |
13-3 |
Detection error of inverter current |
14-0 |
PAM over voltage error |
14-1 |
PAM clock error |
14-2 |
PAM under voltage error |
14-4 |
PFC Module error |
17-0 |
Serial open-circuit |
18-0 |
Serial short-circuit |
18-1 |
Serial erroneous wiring |
18-2 |
High speed serial communication error |
19-0 |
Indoor unit fan error |
20-0 |
EEPROM data error |
20-1 |
External EEPROM initial data reading error |
20-2 |
External EEPROM verify error |
20-3 |
External EEPROM communication error |
21-0 |
Incomplete closing of louver cover or louver closing lever |
22-0 |
Plasmacluster connecting error |
22-1 |
Lock On Sensor error |
22-2 |
Over time of accumulated plasmacluster operation time |
23-0 |
Wrong connect to 200V AC |
24-0 |
Wireless lan module communication error |
24-1 |
Connecting error with wireless lan router |
24-2 |
Internet condition error |
24-3 |
Connecting error with server |
25-1 |
AC clock error |
26-1 |
Indoor unit room temperature thermistor |
26-2 |
Indoor unit pipe temperature thermistor |
28-0 |
Initial error filter cleaning operation |
28-1 |
Error during filter cleaning operation |
28-2 |
Incomplete closing of open panel or front panel, or air filter installation error |
29-0 |
Panel cannot open |
29-1 |
Panel cannot close |
31-0 |
Sub microcomputer error |
31-6 |
Sub microcomputer error |
31-7 |
Sub microcomputer error |