Products Lineup
Phototriac Couplers

Built-in zero-cross circuit type | ||||
(Ta = 25°C) |
Model No. |
Internal connection diagram |
Features |
Approved by safety standards*3 |
Package |
Absolute maximum ratings |
Electro-optical characteristics |
||||
---|---|---|---|---|---|---|---|---|---|---|
UL, CSA |
VDE |
BSI, SEMKO, DEMKO, FIMKO |
ON-state current IT (rms) (A) |
Repetitive peak OFF-state VDRM (V) |
Isolation voltage (AC) Viso (rms) (kV) |
Min. trigger
current IFT (mA) MAX. VD = 4 V, RL = 100Ω |
||||
S2S4A00F |
![]() |
200 V lines, compact |
○ |
○*4 |
– |
Mini-flat 4-pin |
0.05 |
600 |
3.75 |
10*1 |
PC3SH21YFZBH |
200 V lines, compact, reinforced isolation |
○ |
○ |
○ |
4-pin DIP |
0.1 |
600 |
5.0 |
7 |
|
PC3SD21NTZAH |
![]() |
200 V lines, low zero-cross voltage: MAX. 20 V |
○ |
– |
– |
6-pin DIP*2 |
0.1 |
600 |
5.0 |
10 |
PC3SD21NTZBH |
200 V lines, low zero-cross voltage: MAX. 20 V |
○ |
○*4 |
– |
7 |
|||||
PC3SD21NTZDH |
200 V lines, low zero-cross voltage: MAX. 20 V |
○ |
– |
– |
3 |
|||||
PC4SD21NTZCH |
200 V lines, repetitive peak-OFF-state voltage |
○ |
– |
– |
800 |
5 |
||||
PC4SD21NTZDH |
200 V lines, repetitive peak-OFF-state voltage |
○ |
– |
– |
3 |
|||||
PC3SF21YVZAH |
200 V lines, reinforced isolation |
○ |
○ |
○ |
600 |
10 |
||||
PC3SF21YVZBH |
200 V lines, reinforced isolation |
○ |
○ |
○ |
7 |
|||||
PC4SF21YVZBH |
200 V lines, reinforced isolation, repetitive peak-OFF-state voltage |
○ |
○ |
○ |
800 |
7 |
||||
PC4SF21YWPSH |
High impulse noise product |
○ |
○ |
○ |
7 |
*1 VD = 6 V, RL = 100Ω
*2 These are 5th-pin cut type.
*3 Please refer to Specification Sheets for model numbers approved by safety standards.
*4 Optionally available.
|
![]() |
![]() |
![]() |
![]() |
S2S3A00F (Mini-flat 4-pin) |
PC3SH series (4-pin DIP) |
PC3SD series, PC4SD series (6-pin DIP) |
PC3SF series, PC4SF series (6-pin DIP) |
<Notice >
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment
using any SHARP devices shown in catalogs, data books, etc.
Except where specially indicated, models listed on this page comply with the EU RoHS Directive*. For details, please contact SHARP.
* EU RoHS Directive: EU legislation restricting the use of lead, cadmium, hexavalent chromium, mercury, specific brominated flame
retardants (PBB and PBDE), and phthalates (DEHP, BBP, DBP, DIBP).
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment
using any SHARP devices shown in catalogs, data books, etc.
Except where specially indicated, models listed on this page comply with the EU RoHS Directive*. For details, please contact SHARP.
* EU RoHS Directive: EU legislation restricting the use of lead, cadmium, hexavalent chromium, mercury, specific brominated flame
retardants (PBB and PBDE), and phthalates (DEHP, BBP, DBP, DIBP).
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.